POU system is the advancing cooling system for water for injection (WFI). Its core components are sanitary sterile double-tubesheet heat exchangers, designed for real-time temperature control of water points, with high automation, stability and reliability, and can be non-standard customized.
Why POU Medium flow rate: 100L/h - 6000L/h Maintain a flow rate of 1.2 m/s according to ASME guidelines Double tube-sheet heat exchanger to eliminate the risk of cross contamination The working performance is not affected by the change of circuit pressure Adjustable distribution flow at different temperatures Access to user control system for intelligent management Compliance with CFR 21 Part 11 guidelines (optional) Each component is 100% inspected at the factory | |
Eling economy Eling economical type is a mature solution, which is used to take water immediately at the set temperature off the water point. The temperature can be observed through the instrument on the panel. The system is an independent and complete unit, which can realize one-button control easily and conveniently and installed wall-mounted.
Features Convenient and simple operation Single/constant flow water intake Single/constant temperature water intake UL&CE certification Comply with ASME BPE Code
Product information Model: STEC 05 Flow: 100 - 1200 L/H Mode: hot distribution and cold distribution Control: full-automatic one-button switch | |
Eling Advanced Edition Eling Advanced Edition is an independent POU version that can work in fully automatic and manual modes.
Features PLC/HMI based control panel for operation and monitoring Level 3 user security control Single/constant flow water intake Single/constant temperature water intake UL&CE certification Comply with ASME BPE Code
Product information Model: STAC 05/STAC 15 Flow: 100 – 1200 L/H (STAC 05)/300 – 12000 L/H (STAC 15) Mode: hot distribution and cold distribution Control: fully automatic and manual interface Communication: PFC/Ethernet | |
Eling customized version ELing customized version is designed to meet the customization needs of users. Most functions and options can be customized. This version can distribute water for injection at different temperatures and flow rates. Its operation is fully automatic based on PLC and can communicate with other PLC or SCADA.
Features Multiple distribution flow rates Various water intake temperatures Zero dead corner diaphragm valve at header NEMA 4X control cabinet Comply with ASME BPE standards Optional CE&UL certification
Product information Series: Eling-POUr Flow: 100 – 10000 L/H or higher Application: cooling or heating Mode: hot distribution and cold distribution Control: fully automatic and manual interface Independent full-automatic, remote operation Communication options:POU to POU communication, communication with other systems, communication with SCADA/DCS system |